There’s Always a Project
← Field journal

Energy

How much solar and battery storage does a Chiang Mai house need?

Thirty panels fit on the roof sketch. Whether the house can use their output depends on an ordinary detail the sketch leaves out: when the car comes home.

Compare your roof and battery options · Test installed quotes and payback

The brief for this Chiang Mai new build starts with a 15 kWp solar array, a hybrid inverter of at least 10 kW, and a choice between 10 and 20 kWh of battery storage. Each number answers a different question. The panels determine how much energy the house can generate over the day. The inverter limits how much power it can supply at once. The battery determines how much energy can move from a sunny afternoon to an evening or a power cut.

What fits on the roof?

The concept drawing puts the ridge east–west. At an assumed pitch of 20°, the south face takes three rows of eight 500 W panels, giving 12 kWp. Six more panels on the north face add 3 kWp. The earlier house brief considered a 15° pitch. The builder’s final roof dimensions, access clearances and shading will determine which layout fits.

Price the south-facing 12 kWp as one option and the six extra panels as a separate line. Ask for monthly output in kWh for each roof face using the actual pitch, orientation and shade. Add the two estimates month by month, then compare a wet-season month with a sunnier one. An annual total can hide the weeks when there is little surplus to charge a battery. The European Commission’s public tool can provide a first estimate for each face. PVGIS solar generation estimator

What happens when the car comes home?

Five complete months of this household’s charging records imply about 15.5 kWh per day for the EV. That figure comes from money spent and an assumed average charging price. It is a useful starting estimate while home-meter readings are unavailable. At a steady 7 kW, it represents about 2 hours 13 minutes of charging. Home EV charging case study and calculator

If the car is in the driveway at midday, it can use solar left over after the house takes its share. If it arrives after sunset, the same drive creates an evening demand. To see why that changes the battery decision, suppose the rest of the house uses 6 kWh after sunset. With daytime EV charging, the battery has 6 kWh of household demand to cover. With evening EV charging, that rises to about 21.5 kWh. The 6 kWh is an example to replace with a meter reading.

What would a second battery actually deliver?

For this comparison, assume each battery starts the evening full, 90% of its nominal capacity is usable, 20% of that usable energy stays in reserve for outages, and 95% of the dispatched energy reaches the house. These are example settings. Ask the supplier for the warranted usable capacity and reserve behaviour of the exact model.

Energy available for an ordinary evening
Battery optionUsable when fullHeld for outagesDelivered to house
10 kWh nominal9.0 kWh1.8 kWh6.84 kWh
20 kWh nominal18.0 kWh3.6 kWh13.68 kWh

For the 6 kWh evening, either option covers the example load. On the 21.5 kWh evening, the smaller battery leaves roughly 14.7 kWh to buy from the grid. The larger one leaves 7.8 kWh. The second module can shift up to another 6.84 kWh on that evening, provided there was enough daytime surplus to fill it and the equipment can deliver the required power. To value it, count the evenings when both conditions hold and use the import price for those hours. Allow for any export income forgone on the electricity diverted to storage.

What needs to keep running during a power cut?

The proposed EV charger draws about 7 kW and the proposed sauna about 6 kW. Together they could call for 13 kW before ovens or air conditioning come on. Even if a quoted inverter can supply 10 kW continuously in backup mode, that pair exceeds it. More battery capacity alone would leave the power limit in place.

Write down the appliances you want during an outage and how long you want them. For example, a fridge, lights and fans averaging 0.5 kW over four hours need 2 kWh delivered. Ask the installer to check starting loads, battery discharge limits and output per phase as well as stored energy. That gives the backup reserve a purpose you can price.

What to ask the installer to quote

  1. Two roof options. Request the 12 kWp south array and the full 15 kWp layout, with monthly generation for the measured roof and the share the house could use directly.
  2. Two battery options on the same basis. Keep the panels and inverter fixed. Ask for the extra installed price of the second module, its usable kWh and how often the model expects it to fill and discharge. For a new house, use a room-by-room weekday and weekend load schedule until interval meter readings are available.
  3. One backup schedule. List essential circuits, their expected demand and the required hours. Ask the installer to identify the inverter, battery and backup equipment by model, and to confirm the applicable grid connection and export terms with PEA.

One supplier sheet in the project illustrates why those details matter. Its 10 kW inverter package lists sixteen 670 W panels, which add up to 10.72 kWp. Comparing that price directly with a 15 kWp layout would put different amounts of generation on either side of the quotation.

For this house, the smaller modular battery is a reasonable option to price first if the car can charge in daylight. The strongest reason to price the second module is a repeated evening shortfall on days when the roof has surplus energy to store, or a specific need for longer backup. The project has enough evidence to ask for those comparisons. A final purchase size and payback estimate still depend on the measured roof, household demand and like-for-like installed quotes.

For the spending figures behind the household budget, see the household electricity and water bill record.

Sources

The charging and house-energy brief is dated 14 October 2026. The roof layout is an October 2026 concept. The supplier example appears on page 5 of the Solartech Center sheet captured 15 October 2026. The supplier sheet is historical. The roof layout and worked battery comparison are planning examples.